Skip to main content
Data Center Cooling Hydraulic Design Engineer The Company NorthMark Compute & Cloud (NMC²) is backed by dedicated leadership and investment, with a clear mission as it operates at the bleeding edge of technology. Its goal is to scale and enhance the high-performance computing (HPC) and cloud infrastructure that supports its clients' research, production, and delivery, enabling breakthroughs that shape the industries of tomorrow. Its engineers build critical infrastructure to eliminate friction in scientific research, simulations, analysis, and decision-making, accelerating discovery and driving faster innovation. This role designs, sizes, routes, and validates the fluid distribution networks that keep a data center's cooling infrastructure running, treating the facility like a process plant so water, glycol, or dielectric fluids flow continuously to the servers without a leak, a pressure drop, or an interruption. On large campuses this often means two chiller technologies operating at once, absorption chilling driven by waste heat and electric chiller plants, feeding different halls with different platform requirements, so loop architecture, fluid purity, and pressure testing have to work across both rather than assuming one. A pipe sizing error shows up as pressure drop across a data hall; a fluid compatibility mistake, for example an absorption chiller's lithium bromide solution reaching incompatible equipment or seals, causes corrosion inside a live CDU; a redundancy gap in the valve matrix lets a single leak take down far more than the pipe that failed. This role reports to the Principal Engineer / Design Authority, Power and Cooling Systems.
Responsibilities: Hydraulic Design and Loop Architecture: Perform hydraulic modeling, NPSH calculations, and pipe sizing (diameter, wall thickness, material) to minimize friction loss; use Caesar II or AutoPIPE to analyze thermal stress and design expansion joints, loops, and anchors Design separate chilled water, condenser water, and secondary technology loops, and specify CDUs bridging main chilled water lines with the ultra pure fluid loops running into AI racks; design piping and controls that account for absorption and electric chiller plants operating on the same campus with different pressure, temperature, and turndown characteristics Filtration, Routing, and Redundancy: Design side stream filtration, strainers, and air separation to maintain fluid purity and prevent blockages in server cold plate channels Route large bore piping through BIM/Revit, resolving conflicts with electrical busways, cable trays, and structural steel; design double block and bleed and isolation valve matrices so a single leak is contained without dropping the data hall loop, consistent with N+1/2N targets Water Treatment and Fluid Compatibility: Partner with chemical consultants on closed loop water treatment, biocidal dosing, and corrosion inhibition; confirm all materials, gaskets, and seals are compatible with the fluid chemistry in use, including treated water, glycol, dielectric fluid, and absorption chiller solution Testing, Commissioning, and Procurement Support: Write and witness hydrostatic/pneumatic testing scripts and flush to clean protocols; support Level 4/5 functional performance testing of flow control valves, balancing valves, and pump VFDs under simulated load drop or failure Maintain commercial pricing and technical scope as separate documents when supporting vendor procurement, so engineer of record review never mixes cost with design intent Gate and Milestone Accountability: Ensure milestones are met at each gate for loop architecture, design freeze, commissioning readiness, and final acceptance
Requirements: BS in Mechanical Engineering, ABET accredited or equivalent, required; MS in Mechanical or Fluid/Thermal Engineering preferredPE license required, given engineer of record sign off on piping design, testing protocols, and commissioning documentation Proficiency with pipe stress software (Caesar II, AutoPIPE) and working knowledge of ASME B31.3/B31.9 required Experience with data center liquid cooling (direct to chip, immersion, CDU integration) strongly preferred; familiarity with absorption chiller fluid chemistry, including lithium bromide handling, is a plus on mixed chiller technology campuses Liquid cooling design experience: Typically 7 to 10 or more years of mechanical engineering experience with hands on chilled water or process piping design; direct CDU integration experience on data center or comparable process industry projects strongly preferred Hydraulic and stress analysis depth: Demonstrated hydraulic modeling, NPSH, and pipe stress analysis solving for real friction loss and thermal expansion, not rule of thumb sizing Fluid compatibility judgment: A track record specifying materials compatible with glycol, dielectric fluid, treated water, and absorption chiller solution, and partnering with treatment specialists to prevent fouling and corrosion Redundancy and BIM clash resolution: Experience designing isolation and double block and bleed strategies to contain a single leak without disrupting the broader loop, and resolving BIM clashes with electrical and structural before construction Testing and commissioning ownership: Experience writing and witnessing pressure testing scripts and flush to clean protocols calibrated to protect cold plate channels, and verifying valve/VFD response during Level 4/5 commissioning Facility and cross functional fit: Data center, hyperscale, or process industry mission critical experience strongly preferred, given the fluid purity and zero leak tolerance of this asset class; able to communicate fluid system risk clearly to commissioning teams and leadership It is impossible to list every requirement for, or responsibility of, any position. Similarly, we cannot identify all the skills a position may require since job responsibilities and the Company's needs may change over time. Therefore, the above job description is not comprehensive or exhaustive. The Company reserves the right to adjust, add to or eliminate any aspect of the above description. The Company also retains the right to require all employees to undertake additional or different job responsibilities when necessary to meet business needs. Must be legally authorized to work in the United States without the need for employer sponsorship, now or at any time in the future.

Also on the board Same function, level within a rung

Level

Senior

Location

Dallas, TX

Occupation

Mechanical Engineers

Industry

Computing Infrastructure Providers, Data Processing, Web Hosting, and Related Services

Posted

2 days ago

Salary not listed

Estimate · Mechanical Engineers in Texas

$75,810 – $175,210 a year

Median $112,410 ($54.05 an hour)

Apply for this role (opens in a new tab)